Products
Blower and turbines
HT-10/15/20 serie - Blower
The ultra-robust and compact ventilators in the HT10/15/20 series are equipped with an interchangeable aluminum radial-type impeller that can generate static pressure differential of up to 22" of water (6.25 kPa) and flows of up to 4,000 cfm. The ventilators in this series are generally used for industrial applications such as the extraction of air containing fumes, vapours, gas, or certain particle concentrations. They are designed for indoor or outdoor use.
Accessories and options
- Acoustic housing
- Flow control damper
- Coverings and finishing on request
- Explosion proof motor
- Square-to-round transition at the outlet
- Filtration station
- Inclement weather protection
- Blow back damper
- Screen at the inlet or outlet
- Muffler at the inlet or outlet
- Velocity cone
- Control switch or control panel
Technical specifications and performances
| Serie | Motor | Maximum flow | Maximum vacuum | Weight | Inlet Ø | ||
|---|---|---|---|---|---|---|---|
| Blower | Acoustic housing H | Weather cover W - Lb (kg) | |||||
| HT-10 | 1 to 5 HP | 2300 cfm | 9 H2O | 159 to 172 lb | 20 lb | 11 lb | 6” or 8” |
| HT-15 | 5 to 15 HP | 3500 cfm | 15 H2O | 195 to 335 lb | 28 lb | 16 lb | 8”,10” or 12” |
| HT-20 | 15 to 25 HP | 4000 cfm | 22 H2O | 440 to 550 lb | 32 lb | 19 lb | 12”,14” or 16” |
HT-25 serie - Turbo high pressure blower
The HT25 turbo ventilator series are equipped with an interchangeable aluminum radial-type impeller that can generate static pressure differential of up to 40" of water (11.5 Kpa) and flows of up to 10,000 cfm. The turbo ventilators in this series are generally used for industrial applications, such as the extraction of air containing fumes, vapours, gas, or certain particle concentrations. They are designed for indoor or outdoor use.
Accessories and options
- Acoustic housing
- Flow control damper
- Coverings and finishing on request
- Explosion proof motor
- Square-to-round transition at the outlet
- Filtration station
- Inclement weather protection
- Blow back damper
- Screen at the inlet or outlet
- Muffler at the inlet or outlet
- Velocity cone
- Control switch or control panel
Technical specifications and performances
| Serie | Motor | Maximum flow | Maximum vacuum | Weight | Inlet Ø | ||
|---|---|---|---|---|---|---|---|
| Blower | Acoustic housing H | Acoustic housing S | |||||
| HT-25 | 10 to 100 HP | 10000 cfm | 40 H2O | 430 - 1500 lb | 70 lb | 400 lb | 8”,10”,12”,14”, 16”,18” |
HV serie - Turbine
HV102 / HV104
The HV102 and HV104 turbines are mobile multi stage turbines that include a high efficiency filtration module. It works with pressure differential of up to 118" of water column (33.5 Kpa) and flows of up to 220 cfm. They are generally used for industrial applications requiring great mobility. These turbines are CSA certified and work on conventional 120v and 240v currents.
Accessories and options
- 15 or 30-gallon tank
- Mobile cart
- Wall unit
- Carbon or HEPA secondary filtration cartridge
Technical specifications and performances
| Model | Motor | Maximum flow | Maximum vacuum | Weight | Inlet Ø |
|---|---|---|---|---|---|
| HV102 | 2 HP | 107 cfm | 118 H2O | 100 lb | 2 or 3 “ |
| HV104 | 4 HP | 220 cfm | 118 H2O | 125 lb | 2 or 3 “ |
HV205 / HV310
The HV205 and HV310 turbines are multi-stage turbines that work with pressure differential of 100" of water column (28.5 Kpa) and flows of up to 360 cfm. They are generally used for industrial applications requiring high pressures and a limited flow.
Accessories and options
- Acoustic housing
- Coverings and finishing on request
- Explosion proof motor
- Muffler at the inlet or outlet
- Velocity cone
- Particle arrestor or filtration station
- Fuse-free control switch or control panel
Technical specifications and performances
| Model | Motor | Maximum flow | Maximum vacuum | Weight | Inlet Ø | |
|---|---|---|---|---|---|---|
| Turbine | Acoustical housing | |||||
| HV205 | 5 HP | 180 cfm | 100 H2O | 137 lb | 50 lb | 4 “ |
| HV310 | 10 HP | 360 cfm | 100 H2O | 235 lb | 50 lb | 4 “ |
HV510 / HV515
The HV510 and HV515 turbines are double-stage turbines designed and manufactured by Henlex that can generate static pressure differential of up to 120” of water column (34 Kpa) and flows of up to 500 cfm. They are used for fume extraction welding gun systems and various other industrial applications.
Accessories and options
- Coverings and finishing on request
- Explosion proof motor
- Muffler at the inlet or outlet
- Velocity cone
- Particle arrestor or filtration station
- Fuse-free control switch or control panel
Technical specifications and performances
| Model | Motor | Maximum flow | Maximum vacuum | Weight | Inlet Ø | |
|---|---|---|---|---|---|---|
| Turbine | Acoustical housing | |||||
| HV510 | 10 HP | 300 cfm | 120 H2O | 355 lb | 100 lb | 4 “ |
| HV515 | 15 HP | 500 cfm | 120 H2O | 461 lb | 100 lb | 4 “ |
HV1015 / HV1020
The HV1015 and HV1020 turbines are high revolution turbines designed and manufactured by Henlex that can generate static pressure differential of up to 100” of water column (28.5 Kpa) and flows of up to 600 cfm. They are used for fume extraction welding gun systems and various other industrial applications.
Accessories and options
- Acoustic housing
- Coverings and finishing on request
- Explosion proof motor
- Muffler at the inlet or outlet
- Velocity cone
- Particle arrestor or filtration station
- Fuse-free control switch or control panel
Technical specifications and performances
| Model | Motor | Maximum flow | Maximum vacuum | Weight | Inlet Ø | |
|---|---|---|---|---|---|---|
| Turbine | Acoustical housing | |||||
| HV1015 | 15 HP | 400 cfm | 100 H2O | 463 lb | 120 lb | 4 “ |
| HV1020 | 20 HP | 600 cfm | 100 H2O | 505 lb | 120 lb | 4 “ |
HV20 / 25 / 30 SERIE
The turbines in the HV20, HV25 and HV30 series are double-stage turbines designed and manufactured by Henlex that can generate static pressure differential of up to 120” of water column (34 Kpa) and flows of up to 2,000 cfm. They are used for fume extraction welding gun systems and various other industrial applications
Accessories and options
- Coverings and finishing on request
- Explosion proof motor
- Muffler at the inlet or outlet
- Velocity cone
- Particle arrestor or filtration station
- Fuse-free control switch or control panel
Technical specifications and performances
| Model | Motor | Maximum flow | Maximum vacuum | Weight | Inlet Ø | |
|---|---|---|---|---|---|---|
| Turbine | Acoustical housing with muffler HS | |||||
| HV20 | 20, 25, 30, 40 HP | 1300 cfm | 120 H2O | 1300 lb | 320 lb | 8 “ |
| HV25 | 40 , 50 HP | 1600 cfm | 120 H2O | 1400 lb | 320 lb | 8 “ |
| HV30 | 50, 60 HP | 2000 cfm | 120 H2O | lb | 320 lb | 8 “ |
HV35 SERIE
The turbines in the HV35 series are double-stage turbines designed and manufactured by Henlex that can generate static pressure differential of up to 100” of water column (28.5 Kpa) and flows of up to 2,400 cfm. They are used for fume extraction welding gun systems and various other industrial applications.
Accessories and options
- Coverings and finishing on request
- Explosion proof motor
- Muffler at the inlet or outlet
- Velocity cone
- Particle arrestor or filtration station
- Fuse-free control switch or control panel
Technical specifications and performances
| Model | Motor | Maximum flow | Maximum vacuum | Weight | Inlet Ø | |
|---|---|---|---|---|---|---|
| Turbine | Acoustical housing with muffler HS | |||||
| HV35 | 50, 60 HP | 2400 cfm | 100 H2O | 1645 lb | 320 lb | 10 “ |
HV40 / 50 / 60 SERIE
The turbines in the HV40, HV50 and HV60 series are double-stage turbines designed and manufactured by Henlex that can generate static pressure differential of up to 115” of water column (33 Kpa) and flows of up to 5,000 cfm. They are used for fume extraction welding gun systems and various other industrial applications.
Accessories and options
- Coverings and finishing on request
- Explosion proof motor
- Muffler at the inlet or outlet
- Velocity cone
- Particle arrestor or filtration station
- Fuse-free control switch or control panel
Technical specifications and performances
| Model | Motor | Maximum flow | Maximum vacuum | Weight | Inlet Ø | |
|---|---|---|---|---|---|---|
| Turbine | Acoustical housing with muffler HS | |||||
| HV40 | 50, 60, 75 HP | 3000 cfm | 115 H2O | 1800 lb | 320 lb | 10 “ |
| HV50 | 75, 100 HP | 4000 cfm | 115 H2O | 2045 lb | 320 lb | 10 “ |
| HV60 | 100 HP | 5000 cfm | 115 H2O | 2370 lb | 320 lb | 10 “ |